Cisco & Meraki specialists. Across the UK.
+44 203 196 6566 · option 1sales@proxar.co.uk

Connect. Secure. Manage.

Internet Edge Networks

Design Cisco or Meraki internet edge networks around circuits, public addressing and clear responsibilities for carrier faults and network support.

Cisco Partner since 2009 Projects & ongoing support

Illustrative Cisco and Meraki fibre network rack with structured cabling
Your network. Properly considered.Design · Implementation · Support
1,000+

Devices supported
across the UK

20+

Client locations
supported

Nearly 8 Tbps

Traffic handled
at peak time

3 min

Average
response time

Average response is not a resolution time or a contractual guarantee. Support scope and response commitments are agreed for each engagement.

Internet edge networks connect your business to providers and public services. We plan Cisco-led edges around addresses, routes, security and the effect of provider faults. Each connection needs a clear owner and recovery plan. Another circuit or a larger firewall may help, but the complete path must be designed and tested together.

01

The whole path

Understand how sites, providers, cloud networks and security controls fit together.

02

Resilience that can be tested

Separate a second circuit from genuine end-to-end service resilience.

03

Provider coordination

Keep addressing, routing and escalation ownership clear across organisations.

Identify the services that depend on the edge

We map outbound user traffic, published apps, remote access, cloud connections and any private provider handoffs sharing the infrastructure. Each can have different addressing, security and recovery needs. A business using only outbound browsing has a different edge need from one hosting services or relying on external allowlists.

The inventory also includes DNS, identity and management dependencies. An edge outage may prevent engineers reaching the very systems needed to restore it. We identify those circular dependencies early and decide which recovery paths need to remain independent of ordinary production internet access.

Illustrative Cisco and Meraki network operations centre with monitoring displays
01Visibility, monitoring and operational control.
Cisco PartnerCisco Partner
Cisco MerakiCisco Meraki
ISO 9001Quality management
ISO 27001Information security
Cyber EssentialsCyber Essentials
Cyber Essentials PlusCyber Essentials Plus

MCI Network Services is operated by Proxar Ltd. Certifications apply to the certified legal entity and the scope of its certificates. View accreditation information

Establish the routing and addressing model

The design considers provider-assigned or other authorised public address space, static or dynamic routing and the networks that may be advertised. BGP is appropriate for some multi-provider arrangements. But it is not automatically required for every business with two internet connections. The choice follows the addressing and service needs.

Address translation and inbound services are documented alongside routing. A change of circuit can change the public address seen by external systems, affecting allowlists, VPNs and published apps. We identify those dependencies before treating failover as a simple default-route change.

Illustrative Cisco and Meraki equipment in a modern data-centre aisle
02Resilient infrastructure from rack to service path.

A useful starting point

Not sure where to start?

Bring the requirement. We will help you define the engineering work.

Talk to a specialist

Place security controls on the actual paths

Firewalls and related controls need to govern the traffic they are expected to protect. We trace normal and alternative routes, including direct cloud or provider connections, and identify any path that could bypass the intended enforcement point. Management access is separated from ordinary user and app traffic.

The security model also covers routing and device administration. Permitted peers, advertised prefixes and reachable management services require clear control. A high-capacity edge with weak admin ownership can create significant risk even when its forwarding policy appears restrictive.

Illustrative Cisco and Meraki data-centre network infrastructure
03Network infrastructure designed around the workloads it carries.

Design resilience beyond circuit count

Two services can share a local access route, provider equipment, power or an upstream carrier dependency. We review the evidence for diversity and distinguish confirmed independence from an assumption based on supplier names. The architecture should explain which failure cases it tolerates and which remain shared risks.

Capacity during failure is equally important. The surviving connection may need traffic prioritisation or a reduced-service plan. We set out those expectations with the customer, rather than suggesting that a lower-bandwidth backup will necessarily maintain every app's normal experience during a busy period.

Illustrative enterprise Cisco network rack in a modern office environment
04Enterprise switching and routing, built to be operated.

Consider denial-of-service and upstream coordination

An on-site device cannot recover bandwidth that has already been saturated upstream. Where the business needs protection against larger denial-of-service events, we assess the role of the carrier or a specialist service and the supported integration. The scope identifies activation, routing and escalation duties rather than assuming a local firewall setting solves every availability threat.

Provider communication also matters for ordinary incidents. We document circuit identifiers, demarcation points and the evidence needed to distinguish a local fault from a carrier problem. Clear ownership reduces delay when several suppliers are involved in one connection.

Illustrative Cisco and Meraki network rack in a modern office
05The office network: switching, uplinks and structured cabling.

Validate applications and recovery paths

Acceptance tests check expected routes, public addressing, permitted inbound services and representative outbound workflows. Remote access and external allowlists are included where they depend on the edge. Testing only a public ping can miss important app and security failures.

Agreed fault scenarios observe both loss and restoration of links or devices. We record whether sessions survive, reconnect or require other action, and whether the alternative path retains the intended protection. Any untested scenario remains clear in the acceptance record.

We also check the practical demarcation between provider and customer equipment. Interface errors, optical levels where available and agreed handoff tests can help establish who needs to act during an incident. The operating record should make that evidence accessible without requiring engineers to reconstruct the installation from old procurement emails.

Illustrative Cisco and Meraki fibre network rack with structured cabling
06Fibre, switching and the physical path behind the service.

Maintain an edge that can change safely

The handover includes addressing, routing policy, firewall duties, provider contacts and certificate or DNS dependencies. Software updates, circuit changes and new published services should follow a controlled process with an appropriate rollback plan. Monitoring needs to identify lost redundancy and complete outage.

MCI can prepare a new Cisco internet edge design or review a current setup before a provider migration. Share the circuits, public services and availability needs. We can define an edge that supports the business's actual connections and makes the limits of its resilience and security clear.

Illustrative Cisco and Meraki network operations centre with monitoring displays
07Visibility, monitoring and operational control.

Technical references

Illustrative Cisco and Meraki equipment in a modern data-centre aisle
08Resilient infrastructure from rack to service path.

Talk to a specialist

What does your network need next?

Tell us what you are planning, changing or trying to improve. We will help define a practical next step and the engineering scope.

+44 203 196 6566

Choose option 1

sales@proxar.co.uk

UK-wide service.
Most of our engineers are based in Kent, with a focus on London, Sussex, Essex and Berkshire.

Existing customers should use their agreed support and escalation channels. This form is for service enquiries, not a monitored emergency ticket.

Tell us what you need.

A short outline is enough. Please do not include passwords or sensitive network details.

Thank you. Your enquiry has been submitted.

We’ll use these details to respond to your enquiry. Please leave out passwords and sensitive network information. Read our privacy notice.