Cisco & Meraki specialists. Across the UK.
+44 203 196 6566 · option 1sales@proxar.co.uk

Connect. Secure. Manage.

Cisco Industrial Ethernet Design

Design Cisco industrial Ethernet networks around environmental requirements, equipment connectivity, resilience and agreed operational technology boundaries.

Cisco Partner since 2009 Projects & ongoing support

Illustrative Cisco and Meraki data-centre network infrastructure
Your network. Properly considered.Design · Implementation · Support
1,000+

Devices supported
across the UK

20+

Client locations
supported

Nearly 8 Tbps

Traffic handled
at peak time

3 min

Average
response time

Average response is not a resolution time or a contractual guarantee. Support scope and response commitments are agreed for each engagement.

Cisco Industrial Ethernet design starts with the equipment, the site and the process it serves. Heat, power, access and repair needs can matter as much as port speed. We plan supported Cisco links around those conditions. The design explains how devices will talk to each other and how engineers will maintain the network.

01

Cisco-focused engineering

Design around the platform, traffic and failure behaviour you actually operate.

02

Change with evidence

Use pre-checks, acceptance criteria and a documented route back.

03

Operational handover

Keep the configuration, diagrams and responsibilities understandable after delivery.

Define the installation conditions

We establish where switches will be mounted, the expected temperature range, available enclosure space and the local power arrangement. Dust, moisture, vibration and access restrictions may influence the hardware and installation method. The equipment specification should follow documented site needs and the chosen product’s actual ratings rather than a broad assumption that all industrial devices suit every setup.

We also clarify responsibility for cabinets, earthing, electrical protection and physical installation. These activities may require competent site contractors and permissions outside a network setup engagement. Identifying them during design avoids arriving at a maintenance window with suitable switches but no approved way to power or mount them.

Illustrative Cisco and Meraki network rack in a modern office
01The office network: switching, uplinks and structured cabling.
Cisco PartnerCisco Partner
Cisco MerakiCisco Meraki
ISO 9001Quality management
ISO 27001Information security
Cyber EssentialsCyber Essentials
Cyber Essentials PlusCyber Essentials Plus

MCI Network Services is operated by Proxar Ltd. Certifications apply to the certified legal entity and the scope of its certificates. View accreditation information

Inventory the connections and protocols

Controllers, operator stations, cameras and engineering laptops may use the network in different ways. The same applies to gateways into business systems. We record port types, speeds, addresses, multicast traffic and supplier limits. Some systems need a stable path within one local segment. Others can use a routed path between networks.

The design must distinguish a confirmed need from a historical convention. A supplier may require a particular topology or prohibit an unapproved change. We record that constraint and seek clarification where it conflicts with the wider architecture. Network convenience should not silently override equipment support conditions or operational safety decisions.

Illustrative enterprise Cisco network rack in a modern office environment
02Enterprise switching and routing, built to be operated.

A useful starting point

Not sure where to start?

Bring the requirement. We will help you define the engineering work.

Talk to a specialist

Choose the topology around failure consequences

A star, ring or dual-network arrangement has different installation and operating implications. We consider the available cable routes, switch roles, supported recovery mechanisms and the effect of a failed access device. A redundant uplink cannot preserve a controller connected to a single failed access switch through one cable.

Where specialised redundancy is proposed, the design checks support across the relevant devices and endpoints. Similar marketing descriptions do not prove interoperability. The related Industrial Network Resilience service develops failure scenarios and acceptance tests so the topology can be judged against an actual recovery need.

Illustrative Cisco and Meraki fibre network rack with structured cabling
03Fibre, switching and the physical path behind the service.

Plan addressing and manageable boundaries

The address plan helps engineers during repairs and calls with suppliers. We record fixed addresses, devices that rely on DHCP, management addresses and overlapping ranges used by machinery. Changing those addresses may also mean changing a control system. Its supplier may need to take part in that separate work.

We then decide where Layer 2 domains should end and how approved traffic reaches other operational zones or business systems. Large shared broadcast domains can make faults harder to contain, but introducing routed boundaries without checking app behaviour can break legitimate services. The design records both the intended separation and the permitted communications.

Illustrative Cisco and Meraki equipment in organised data-centre racks
04Data-centre connectivity with clear physical and logical boundaries.

Account for cabling and power dependencies

Fibre may be appropriate for distance, electrical isolation or environmental reasons, while copper may suit local endpoints. We specify supported optics, connector types and cable needs, with appropriate testing of the installed path. The chosen link speed must be achievable across the whole connection, not only advertised by one port.

Power design includes the available feeds, supported switch inputs and the effect of losing a supply. Where endpoints use PoE, their needs contribute to the switch and cabinet budget. We identify shared dependencies so that two nominally redundant switches do not inadvertently rely on the same unprotected electrical connection.

Illustrative Cisco and Meraki industrial network equipment in a plant environment
05Network engineering for operational and industrial environments.

Build access and monitoring into the design

Management access should be separated from ordinary production traffic where appropriate and restricted to authorised systems and people. We set out admin authentication, time synchronisation, logging and backup of the settings needs that fit the chosen platform. Monitoring needs useful alerts without placing unnecessary load on fragile endpoints.

We also plan how an engineer reaches equipment during a fault. A management path that depends on the failed production network may be unavailable when needed most. Local access arrangements, cabinet documentation and replacement procedures form part of the operational design rather than being left to an incident response improvisation.

Illustrative Cisco and Meraki data-centre network infrastructure
06Network infrastructure designed around the workloads it carries.

Produce a design that can be commissioned

Deliverables can include topology drawings, addressing and port schedules, equipment needs, setup standards, dependency lists and acceptance criteria. We check what can be checked in a staging setup and what requires a controlled site test. Any untested assumption is recorded with an owner and a resolution route.

MCI can review a proposed industrial installation or develop a design for a current setup that has grown without consistent records. Share the site conditions, equipment list and operating constraints. We will define the Cisco network work, supplier interfaces and commissioning evidence before the rollout scope is finalised.

Illustrative Cisco and Meraki network rack in a modern office
07The office network: switching, uplinks and structured cabling.

Talk to a specialist

What does your network need next?

Tell us what you are planning, changing or trying to improve. We will help define a practical next step and the engineering scope.

+44 203 196 6566

Choose option 1

sales@proxar.co.uk

UK-wide service.
Most of our engineers are based in Kent, with a focus on London, Sussex, Essex and Berkshire.

Existing customers should use their agreed support and escalation channels. This form is for service enquiries, not a monitored emergency ticket.

Tell us what you need.

A short outline is enough. Please do not include passwords or sensitive network details.

Thank you. Your enquiry has been submitted.

We’ll use these details to respond to your enquiry. Please leave out passwords and sensitive network information. Read our privacy notice.